 MIXERS TRIPLE-BALANCED
LO = +17 dBm SURFACE MOUNT
FREQUENCY RANGE (MHz) CONVERSION LOSS (dB)
XMB FULL BAND TYP/MAX
VERY HIGH DYNAMIC RANGE
133
LO-RF ISOLATION (dB)
LB TYP/MIN MB TYP/MIN UB TYP/MIN
159
LO-IF ISOLATION (dB)
PACKAGE LB TYP/MIN MB TYP/MIN UB TYP/MIN
PIN OUT
MODEL
RF/LO
IF
TYP/MAX
5 - 1000 25 - 1800 750 - 2500
5 - 1000 25 - 1000 50 - 880
6.5/8 7.5/8.5 7/8.5
7.5/9.5 8/9 8/9.2
35/20 50/30 44/35
40/30 45/25 --/--
30/23 35/20 40/30
30/20 35/15 38/28
30/20 25/15 --/--
25/20 23/15 25/20
159 133 133
1 2 2
SLD-K5M SMD-C5M SMD-C7M*
*XMB = 750 - 1000 MHz *LB = 750 - 1200 MHz *UB = 1200 - 2500 MHz
THROUGH HOLE (RELAY)
FREQUENCY RANGE (MHz) CONVERSION LOSS (dB)
XMB FULL BAND TYP/MAX
102
LO-RF ISOLATION (dB)
LB TYP/MIN MB TYP/MIN UB TYP/MIN
103
LO-IF ISOLATION (dB)
PACKAGE LB TYP/MIN MB TYP/MIN UB TYP/MIN
105
PIN OUT
MODEL
RF/LO
IF
TYP/MAX
0.05-200 5-1200 10-2500 10-2500 10-3000 500-3700 500-3700 NOTES:
0.05-200 1-1200 10-1000 10-1000 10-1000 500-1000 500-1000
5.5/6.5 6/7 7/8 7.0/8.0 8/11 --/---/--
6.5/7 7/8.5 7.5/8.5 7.5/8.5 10/12 9.5/11.5 9.5/11.5
45/30 50/35 55/35 55/35 29/20 45/25 45/25
50/45 45/30 45/30 45/30 25/18 45/25 45/25
45/40 40/25 35/25 35/25 23/14 45/25 45/25
35/25 40/30 35/20 35/20 27/20 40/20 40/20
40/35 35/25 30/20 30/20 25/12 40/20 40/20
35/20 35/20 27/20 27/20 23/16 40/20 40/20
102 102 103 105 102 103 105
3 4 3 5 3 3 5
CMP-206 CMP-231 CMP-205 CMP-305 CMP-2A8 CMP-210 CMP-310
PIN-OUT TABLE RF #1 #2 #3 #4 #5 4 1 1 1 1 LO 1 2 8 3,4* 4 IF 5 3 3 8 2 GND 2,3,6 4,5,6 2,5,6,7 2,5,6,7 3 CASE GND --2,5,6,7 2,5,6,7 3 NO CONN. --4 ---
1. 1dB Compression Point = +14 dBm (Typ) 2. IP3 (Input) = +26 dBm (Typ) 3. As IF frequency decrease below LF towards DC, conversion loss increases up to 8 dB higher than maximum. 4. Maximum Input Power without damage = 500 mW ave. cw XMB= 2LF to HF/2 FULL BAND = LF to HF LB= LF to 10LF MB = 10LF to HF/2 UB= HF/2 to HF
* Pins must be connected together GND = Ground externally For pin location and package outline drawings, see back pages.
201 McLean Boulevard * Paterson, New Jersey 07504 * Tel: (973) 881-8800 * Fax: (973) 881-8361 E-Mail: sales@synergymwave.com * World Wide Web: http://www.synergymwave.com
[ 79 ]
MIXERS TRIPLE-BALANCED
LO = +17 dBm THROUGH HOLE (TO-CAN)
FREQUENCY RANGE (MHz) CONVERSION LOSS (dB)
XMB FULL BAND TYP/MAX
VERY HIGH DYNAMIC RANGE
104
LO-RF ISOLATION (dB)
LB TYP/MIN MB TYP/MIN UB TYP/MIN
122
LO-IF ISOLATION (dB)
PACKAGE LB TYP/MIN MB TYP/MIN UB TYP/MIN
123
PIN OUT
MODEL
RF/LO
IF
TYP/MAX
0.05 - 200 10 - 2500 10 - 2500 500 - 3700
0.05 - 200 10 - 1000 10 - 1000 500 -1000
5.5/6.5 7/8 7/8 --/--
6.5/7 7.5/8.5 7.5/8.5 9.5/11.5
45/30 55/35 55/35 45/25
50/45 45/30 45/30 45/25
45/40 35/25 35/25 45/25
35/25 35/20 35/20 40/20
40/35 30/20 30/20 40/20
35/30 27/20 27/20 40/20
123 104 122 122
1 1 2 2
CMP-506 CMP-505 CMP-605 CMP-610
FLAT-PACK
FREQUENCY RANGE (MHz) CONVERSION LOSS (dB)
XMB FULL BAND TYP/MAX
LO-RF ISOLATION (dB)
LB TYP/MIN MB TYP/MIN UB TYP/MIN
LO-IF ISOLATION (dB)
PACKAGE LB TYP/MIN MB TYP/MIN UB TYP/MIN
PIN OUT
MODEL
RF/LO
IF
TYP/MAX
10 - 2500 500 - 3700
10 - 1000 500 -1000
7/8 --/--
7.5/8.5 9.5/11.5
55/35 45/25
45/30 45/25
35/25 45/25
35/20 40/20
30/20 40/20
27/20 40/20
101 101
3 3
CMF-105 CMF-110
COAXIAL
FREQUENCY RANGE (MHz) CONVERSION LOSS (dB)
XMB FULL BAND TYP/MAX
LO-RF ISOLATION (dB)
LB TYP/MIN MB TYP/MIN UB TYP/MIN
LO-IF ISOLATION (dB)
PACKAGE LB TYP/MIN MB TYP/MIN UB TYP/MIN
PIN OUT
MODEL
RF/LO
IF
TYP/MAX
0.05 - 200 0.05 - 200 10 - 2500 10 - 1000 500 - 3700 500 -1000
5.5/6.5 7/8 --/--
6.5/7 7.5/8.5 9.5/11.5
45/30 55/35 45/25
50/45 45/30 45/25
45/40 35/25 45/25
35/25 35/20 40/20
40/35 30/20 40/20
35/30 27/20 40/20
110 110 110
4 4 4
CMK-706* CMK-705S CMK-710S
NOTES:
1. 1dB Compression Point = +14 dBm (Typ) 2. IP3 (Input) = +26 dBm (Typ) 3. As IF frequency decrease below LF towards DC, conversion loss increases up to 8 dB higher than maximum. 4. Maximum Input Power without damage = 500 mW ave. cw XMB= 2LF to HF/2 FULL BAND = LF to HF LB= LF to 10LF MB = 10LF to HF/2 UB= HF/2 to HF #1 #2 #3 #4
* Connector
PIN-OUT TABLE RF 2 1 1 1 LO 5 3 4 3 IF 11 2 5 2 GND
style: "B" = BNC, "T" = TNC, N" = Type N, "S" = SMA
CASE GND
All Others All Others 4 4 2,3,6,7,8 2,3,6,7,8 ---
GND = Ground externally For pin location and package outline drawings, see back pages.
201 McLean Boulevard * Paterson, New Jersey 07504 * Tel: (973) 881-8800 * Fax: (973) 881-8361 E-Mail: sales@synergymwave.com * World Wide Web: http://www.synergymwave.com
[ 80 ]


▲Up To Search▲   

 
Price & Availability of CMP-205

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X